Light-flooded parking structures should fundamentally be favoured. However, if they feature insufficient artificial lighting on the inside and unobstructed daylight openings (windows) are located in the main driving directions, those can lead to unbearable glare, loss of orientation and thus become a safety risk. High reflectance and additional lighting of indoor areas reduce brightness contrasts and consequently glare. If there is visual contact to outside daylight from the main movement directions, the illuminance values (see table) must be doubled for these areas. The federal parking association Bundesverband Parken e. V. (www.parken.de) which has been active in Germany since 1968 represents the operators of more than 2.100 parking garages, underground parking garages and other large-format parking facilities with nearly 1 million parking spots. This equates to roughly 80% of all parking garages in Germany. The association upholds the idea of a user-friendly, bright parking garage and emphasises the wishes of users in terms of safety, attractiveness, clarity and cleanliness in parking garages. Light and colour, which are closely connected to orientation and safety, are paramount design basics in this respect. The lighting requirements contained in standard EN 12464-1 correspond to this objective from the association’s point of view.
Figure 3.152: To rate spatial perception through lighting, the semi-cylindrical illuminance EV is used as a quality parameter. It is the sum of vertical illuminance Esz on a half-cylinder (right) and a measure for the recognisability of three-dimensional structures (left).
Figure 3.153: Example for lighting design in a parking garage according to EN 12464-1, horizontal illuminance distribution (isolux lines) in lx
Extreme peripheral areas Photometric requirements according to EN 12464-1
In/out ramps Traffic lanes Parking spaces Extreme peripheral areas Lighting design Photometric requirements according to EN-12464-1
Introduction Visual needs Need for orientation Non visual needs
Guidelines Overview Work places Visual task area Surrounding area Illuminance Luminance distribution Limitation of glare Lighting direction, modelling Aspects of colour Flicker and stroboscopic effects Daylight
Maintenance Factor Light and safety at work Light and non-visual effects Light and economy Light and environment Lighting design Lighting measurement Emergency lighting
Lighting of traffic zones and geneal areas in buildings Lighting of industrial activities and crafts Lighting of offices and VDU workstations Lighting of design and CAD offices Lighting of sports facilities Lighting of health care facilities Lighting of geriatric care facilities and nursing homes Lighting of public areas Lighting of salesrooms Lighting of educational facilities Lighting of traffic areas Lighting of car parks Ligthing of further indoor spaces
Luminaires The enhanced concept of quality Photometric classification Photometric properties Photo biology safety Mounting and electrical connection Luminaire labelling Luminaire operation LED luminaire operation Operation of FL luminaires Electrical safety Fire protection Electromagnetic safety Mechanical safety Chemical and miscellaneous impact Acoustic properties Ventilation properties
Firehazardous locations Room with bathtubs and showers Swimming baths Exterior installations Agricultural and gardening plant locations Food industry Clean rooms Requirements on mediacal rooms Emergency light installations
Luminaire selection chart
Light management application and function Presence detection Daylight-dependent regulation Interfaces Building management, KNX and other bus systems
Light sources types Characteristics of light sources
ABC, DF, G, ILM, NO, P, QRSUV, W
Subject index
StandardsGuidelines and instructionsEuropean directives and regulationsFurther publications
Lighting societies
Standardisation institutes
Select a different country or region to view content for your location.
Select how or where you would like to share this page.
Headquarters
Postbox 1960D-59753 Arnsberg
TRILUX ONE is your personal e-business platform. It bundles all important information and supports you in all processes related to your new lighting.
An error has occurred.